Skip to product information
1 of 1

Printer Genie Ltd

JC92-02470A Fuser Reset Chip for Samsung SL-X7600GX / SL-X7600LX

JC92-02470A Fuser Reset Chip for Samsung SL-X7600GX / SL-X7600LX

Regular price £35.00 GBP
Regular price Sale price £35.00 GBP
Sale Sold out
Shipping calculated at checkout.
Condition: New

New

New UK supplier GenieCare™ support included

Fuser Reset Chip for Samsung SL-X7600GX / SL-X7600LX — New

Clear the "Replace Fuser" Warning Without Buying a Full Fuser Unit

New fuser reset chip for Samsung SL-X7600GX / SL-X7600LX — new, supplied by Printer Genie.

  • Direct-fit PBA-FUSER logic board for Samsung SL-X7600GX / SL-X7600LX
  • OEM references: JC92-02470A (primary) / JC41-00748A (alias)
  • Clears "Replace Fuser" and fuser end-of-life warnings
  • Typical installation time: 10–20 minutes after fuser removal
  • 12-month warranty against defects
  • UK supplier — despatched from our warehouse
  • 30 days GenieCare™ Expert Support — installation guidance included
Fuser Reset Chip for Samsung SL-X7600GX / SL-X7600LX — New | Printer Genie UK

Important — what this chip does and does not do

✓ This chip WILL clear:
  • "Replace Fuser Unit" message
  • "Fuser Life Warning" message
  • Fuser end-of-life counter warnings
  • Scheduled replacement prompts
✗ This chip will NOT fix:
  • Electrical fuser faults (50.x, 50.7F, U1-xxxx, E000–E002)
  • Physical fuser damage or mechanical failure
  • Toner smudging caused by a worn fuser roller
  • "Fuser not installed" or connection errors

If your printer is showing an electrical fault code rather than an end-of-life message, you need a full fuser unit replacement — not a reset chip. Contact us if you're unsure which applies to your situation.

Is This the Right Part?

Your printer displays "Replace Fuser Unit"This message indicates the fuser's page count has reached its rated end-of-life threshold. The printer has tracked the counter and is prompting replacement. If the fuser is otherwise working correctly — no smudging, no electrical fault code — this chip resets the counter and clears the message without replacing the entire fuser. Your fuser was recently replaced and the warning won't clearOn some models, fitting a new fuser does not automatically reset the counter — the logic board inside the fuser assembly still carries the old data. Replacing the PBA-FUSER board is the correct way to clear the warning after a fuser replacement on these models.
You want to extend fuser life cost-effectivelyIf the fuser is mechanically sound — no toner rub-off, no ghosting, no unusual noise — replacing only the logic board is a cost-effective way to clear the end-of-life warning and continue using the existing fuser assembly. Not sure? Ask us before orderingIf your printer is showing an error code (50.x, E000, C6000, U1-xxxx) rather than a scheduled replacement message, this chip is not the right solution. Contact us — we'll help identify whether you need a reset chip or a full fuser unit.

Specifications

Component Fuser reset chip — PBA-FUSER logic board (PCB-FUSER)
Primary OEM part number JC92-02470A
Alias / alternative part numbers JC41-00748A — also referenced as PBA-FUSER, PCB-FUSER, fuser logic board
Condition New
Fitment Inside the fuser assembly — swap the logic board and re-seat the harness connector
Typical installation time 10–20 minutes after fuser removal
Compatible printers Samsung SL-X7600GX, SL-X7600LX
Warranty 12 months against manufacturing defects
Weight & delivery Courier delivery, tracked

Compatible Printers

This chip fits the fuser assembly in the following Samsung models. If your model is not listed, contact us before ordering — fuser board part numbers vary between models and regional variants.

Model Part Number Confirmed Notes
Samsung SL-X7600GX JC92-02470A Confirmed compatible
Samsung SL-X7600LX JC92-02470A Confirmed compatible

What's Included

  • 1 × Fuser reset chip — PBA-FUSER board (JC92-02470A / JC41-00748A)
  • 30 days GenieCare™ Expert Support — installation guidance included from date of purchase
  • GenieCare™ Expert Support continues when you order toner from us

Installation Notes

Allow the fuser to cool fully before handling. The fuser assembly reaches high temperatures during normal operation. Power off the printer and wait at least 30 minutes before removing the fuser.

  1. Power off the printer and disconnect from the mains. Wait at least 30 minutes.
  2. Remove the fuser unit from the printer — rear access panel, release locking levers, slide out.
  3. Open the fuser housing to access the PBA-FUSER logic board.
  4. Photograph the harness connector positions before disconnecting (useful reference).
  5. Disconnect the harness connectors from the old board.
  6. Fit the new PBA-FUSER board and reconnect all harness connectors fully.
  7. Reassemble the fuser housing and reinstall the fuser into the printer.
  8. Power on and run 5–20 test prints to confirm the warning has cleared and output is clean.

If you need help at any step — including a photo check of the board and connector positions — contact us via GenieCare™ Expert Support. Installation guidance is included with this purchase.

Support

30 days GenieCare™ Expert Support — included free from date of purchase. Our team can help with board installation, harness connector identification, and diagnosis if the warning persists after fitting.

GenieCare™ Expert Support continues — order your Samsung CLT-806S series toner from Printer Genie after completing this repair and support carries on automatically. No subscription. No sign-up.

GenieCare™ Expert Support covers remote diagnosis, guidance, and advice. It does not constitute an on-site repair service.

GenieCare™ Expert Support – Included with This Part

GenieCare Expert Support — Printer Genie

30 days installation support — then keeps going as long as you buy toner from us

Order your Samsung CLT-806S series toner from Printer Genie after this repair and GenieCare™ Expert Support stays active. Real printer experts. No call centres. No subscription.

GenieCare™ Expert Support covers

✓ PBA-FUSER board installation guidance ✓ Harness connector identification
✓ Fault diagnosis if warning persists ✓ Error code help — chip vs fuser unit
✓ Print quality troubleshooting ✓ Repair versus replacement advice

Order Samsung CLT-806S series toner to keep GenieCare™ Expert Support active

Samsung CLT-K806S Black CLT-K806S ~45,000 pages
Samsung CLT-C806S / M806S / Y806S CLT-C806S / M806S / Y806S ~30,000 pages each
Shop Samsung CLT-806S series Toner
Keeps GenieCare™ Support Active
Fit this chip 30 days support free Order Samsung CLT-806S series toner Keep buying toner — support never stops

GenieCare™ Expert Support stays active with each toner order — no subscription, no sign-up. Covers remote diagnosis, guidance, and advice. Does not replace any product warranty. Search SL-X7600 on our store for paper jam repair kits for this printer.

Frequently Asked Questions

My printer shows a fuser error code — will this chip fix it?

This depends on the specific code. This chip clears scheduled end-of-life warnings ("Replace Fuser Unit", "Fuser Life Warning"). It does not fix electrical fault codes such as 50.x, 50.7F, U1-xxxx, E000, or E001 — those indicate a hardware failure requiring a full fuser unit replacement. If you're not certain which type of message you have, contact us before ordering and we'll help you identify the right solution.

Why is the fuser warning showing on a recently replaced fuser?

On some Samsung models, the end-of-life counter is stored on the logic board (PBA-FUSER) inside the fuser assembly — not on the printer's main board. Fitting a new fuser housing does not reset this counter if the old logic board is transferred or if the new fuser shares the same counter data. Replacing the PBA-FUSER board with this chip resets the counter correctly.

Do I need to remove the entire fuser to fit this chip?

Yes — the PBA-FUSER board is located inside the fuser assembly housing. You need to remove the fuser from the printer and open the housing to access the board. This takes 10–20 minutes on most models. Our GenieCare™ Expert Support team can guide you through the process, including harness connector positions, if you need it.

What if the warning doesn't clear after fitting the chip?

If the fuser warning persists after fitting, contact us. The most likely causes are an incorrectly seated harness connector, or the printer displaying an electrical fault code rather than an end-of-life warning. Our team will help diagnose the issue — if the chip is the wrong solution for your specific fault, we'll advise on the correct part.